FEATURES |
---|
– Check Valve |
– Compression Fitting for 1/4″ Airline (Pre-installed) |
– Vibration Isolators |
– Mounting Hardware |
– Installation Instructions |
– |
– |
– |
– |
– |
SPECIFICATIONS |
---|
– 12-Volt |
– Gear Driven Motor |
– Duty Cycle: 15% @ 90 PSI |
– Max. Working Pressure: 90 PSI |
– Max. Air Tank Size: 1.0 Gallon |
– Max. Amp Draw: 10-Amps |
– Ingress Protection Rating: IP54 |
– Max Ambient Temp: +158°F |
– Min Ambient Temp: -40°F |
– Dimensions: 5″L x 2.9″W x 4.8″H |
– Net Weight: 1.6 lbs. |
RECOMMENDED COMPONENTS | |||||
---|---|---|---|---|---|
– 12V Relay (P/N 93940) | |||||
– 12V Sealed Relays (P/N 93944, 93950) | |||||
– Pressure Switch (P/N 90105) | |||||
– Leader Hose w/out Check Valve (P/N 92801, 92803) |
|||||
– Leader Hose w/ Check Valve (P/N 92807) | |||||
– | |||||
– | |||||
– | |||||
– | |||||
– |
Please Note: Use thread sealant for proper installation. Thread tape is not recommended. Properly sealed, recommended torque for 1/8” is 10 ~ 11 ft. lbs. Recommended torque for 1/4” and 3/8” is 16 ~ 18 ft. lbs.
PERFORMANCE DATA
PSI | CFM | A | BAR | LPM | A |
---|---|---|---|---|---|
0 | 1.15 | 6 | 0 | 33.0 | 6 |
10 | 0.59 | 7 | 1.0 | 17.0 | 7 |
20 | 0.55 | 8 | 2.0 | 15.0 | 8 |
30 | 0.52 | 8 | 3.0 | 13.0 | 9 |
40 | 0.48 | 9 | 4.0 | 12.0 | 9 |
50 | 0.45 | 9 | 5.0 | 10.0 | 9 |
60 | 0.41 | 9 | |||
70 | 0.38 | 9 | |||
80 | 0.33 | 10 |
* Supply Voltage: 13.8 Volts
FILL RATES
0.5 Gallon Tank | Fill Rate |
---|---|
0 to 80 PSI | 50 sec. (± 05 sec.) |
45 to 80 PSI | 23 sec. (± 03 sec.) |
55 to 80 PSI | 19 sec. (± 03 sec.) |
1.0 Gallon Tank | Fill Rate |
0 to 80 PSI | 1 min. 28 sec. (± 05 sec.) |
45 to 80 PSI | 36 sec. (± 03 sec.) |
55 to 80 PSI | 33 sec. (± 05 sec.) |
* Due to redundant restrictions added to apparatus, for flow rate testing, actual flow rate at 0 psi may vary.