FEATURES |
---|
– Gas Station-Style Tire Inflation Gun with 160 PSI Gauge |
– Thermal Overload Protector |
– Automatic Shut-Off Function |
– Upgraded Vibration Isolators |
– 30 ft. Braided inside Black Coil Hose |
– 40-amp Inline Fuse Holder |
– Storage Bag for Hose and Tire Inflation Gun |
– Air Line for Remote Mount Air Filter |
– Upgraded Vibration Isolators |
– Mounting Hardware |
– (2) Replacement Air Filter Elements |
– Installation Instructions |
SPECIFICATIONS |
---|
– 12-Volt |
– Permanent Magnetic Motor |
– Duty Cycle: 33% @ 100 PSI |
– Max. Working Pressure: 150 PSI |
– Max. Amp Draw: 30-Amps |
– Ingress Protection Rating: IP54 |
– Max Ambient Temp: +158°F |
– Min Ambient Temp: -40°F |
– Dimensions: 10.83″L x 4.13″W x 7.28″H |
– Net Weight: 10.70 lbs. |
– Power Cord Length: 8 ft. |
– Air Hose Length: 30 ft. |
– |
RECOMMENDED COMPONENTS | |||||
---|---|---|---|---|---|
– 30ft. Inside Braided Black Extension Hose (P/N 00031) | |||||
– | |||||
– | |||||
– | |||||
– | |||||
– | |||||
– | |||||
– | |||||
– | |||||
– | |||||
– | |||||
– |
* For 12V Only.
Please Note: Use thread sealant for proper installation. Thread tape is not recommended.
Properly sealed, recommended torque for 1/8” is 10 ~ 11 ft. lbs. Recommended torque for 1/4” and 3/8” is 16 ~ 18 ft. lbs.
PERFORMANCE DATA
PSI | CFM | A | BAR | LPM | A |
---|---|---|---|---|---|
0 | 2.30 | 17 | 0 | 65.1 | 17 |
10 | 2.13 | 19 | 1.0 | 58.4 | 20 |
20 | 1.98 | 21 | 2.0 | 53.0 | 23 |
30 | 1.86 | 23 | 3.0 | 48.5 | 24 |
40 | 1.75 | 24 | 4.0 | 44.2 | 26 |
50 | 1.64 | 25 | 5.0 | 40.2 | 27 |
60 | 1.54 | 26 | 6.0 | 37.0 | 28 |
70 | 1.44 | 27 | 7.0 | 33.3 | 29 |
80 | 1.37 | 27 | 8.0 | 30.1 | 28 |
90 | 1.28 | 28 | 9.0 | 27.0 | 28 |
100 | 1.19 | 29 | 10.0 | 22.1 | 27 |
110 | 1.11 | 29 | |||
120 | 1.04 | 28 | |||
130 | 0.95 | 28 | |||
140 | 0.85 | 27 | |||
150 | 0.71 | 27 |
* Supply Voltage: 13.8 Volts
FILL RATES
31″ x 10.5″ | Fill Rate |
---|---|
0 to 30 PSI | 3 min. 00 sec. (± 10 sec.) |
15 to 30 PSI | 1 min. 35 sec. (± 05 sec.) |
33″ x 12.5″ | Fill Rate |
0 to 30 PSI | 4 min. 20 sec. (± 10 sec.) |
15 to 30 PSI | 2 min. 05 sec. (± 05 sec.) |
35″ x 12.5″ | Fill Rate |
0 to 30 PSI | 5 min. 20 sec. (± 15 sec.) |
15 to 30 PSI | 2 min. 45 sec. (± 05 sec.) |
* Due to redundant restrictions added to apparatus, for flow rate testing, actual flow rate at 0 psi may vary.