SPECIFICATIONS |
---|
– 12-Volt |
– Permanent Magnetic Motor |
– Duty Cycle: 100% @ 100 PSI – Duty Cycle: 55% @ 200 PSI |
– Max. Working Pressure: 200 PSI |
– Max. Amp Draw: 44-Amps |
– Ingress Protection Rating: IP67 |
– Max Ambient Temp: +158°F |
– Min Ambient Temp: -40°F |
– Dimensions: 18.5″L x 5.9″W x 13.5″H |
– Net Weight: 30 lbs. |
– |
– |
– |
– |
– |
– |
– |
PRE-INSTALLED |
---|
– 2.0 Gallon 5-Port Air Tank |
– (2) 380C Air Compressors w/Thermal Overload Protectors |
– (2) 1/4” Stainless Steel Braided Leader Hoses |
– (2) 1/4” JIC Fittings on Leader Hoses |
– 1/4” NPT Swivel to 1/4” NPT Swivel |
– T-Fitting (Remote Mount Filter) |
– 1/4” NPT Drain Cock |
– Sealed Pressure Switch with Delphi Connectors (165 PSI On, 200 PSI Off) |
(2) Loomed Compressor Wires Terminated with Delphi Connectors |
– Inline Fuse Holder with Fuse |
– 1/4” NPT Safety Valve |
– (4) 1/4” NPT M Recessed Plugs |
– |
– |
INCLUDED IN KIT |
---|
– Crossmember Mounting Bracket |
– 60-Amp Fuse & Fuse Holder |
– 80-Amp Relay |
– (2) 1/4” BSP Adapters for Air Lockers |
– T-Fitting 1/4″ NPT F x 1/4″ NPT F x 1/4″ NPT M |
– 1/8″ to 1/4″ NPT Reducer |
– Wiring Harness with Delphi Connectors |
– (2) Delphi Connector Plug Kits |
– Billet 1/4” NPT x 6-Port Manifold and Mounting Bracket |
– Air Filter Housing with Installed Element |
– (2) Replacement Air Filter Elements |
– Dash Panel Air Pressure Gauge (0-200 PSI Illuminated) |
– Air Pressure Regulator |
– 15ft. DOT Air Line |
– |
– |
Please Note: Use thread sealant for proper installation. Thread tape is not recommended.
Properly sealed, recommended torque for 1/8” is 10 ~ 11 ft. lbs. Recommended torque for 1/4” and 3/8” is 16 ~ 18 ft. lbs.
PERFORMANCE DATA
PSI | CFM | A | BAR | LPM | A |
---|---|---|---|---|---|
0 | 2.54 | 28 | 0 | 72.0 | 28 |
10 | 2.42 | 29 | 1.0 | 67.0 | 30 |
20 | 2.30 | 31 | 2.0 | 61.7 | 33 |
30 | 2.17 | 33 | 3.0 | 57.5 | 34 |
40 | 2.07 | 34 | 4.0 | 53.5 | 36 |
50 | 1.95 | 35 | 5.0 | 49.8 | 37 |
60 | 1.87 | 36 | 6.0 | 46.4 | 39 |
70 | 1.78 | 37 | 7.0 | 43.3 | 41 |
80 | 1.70 | 38 | 8.0 | 40.3 | 43 |
90 | 1.61 | 39 | 9.0 | 37.2 | 44 |
100 | 1.54 | 41 | 10.0 | 34.5 | 42 |
110 | 1.46 | 42 | 11.0 | 31.8 | 41 |
120 | 1.40 | 43 | 12.0 | 29.2 | 40 |
130 | 1.32 | 44 | 13.0 | 26.6 | 38 |
140 | 1.25 | 43 | 14.0 | 23.7 | 37 |
150 | 1.19 | 42 | |||
160 | 1.12 | 41 | |||
170 | 1.06 | 40 | |||
180 | 0.99 | 39 | |||
190 | 0.93 | 38 | |||
200 | 0.86 | 37 |
FILL RATES
2.0 Gallon Tank | Fill Rate |
---|---|
0 to 200 PSI | 2 min. 35 sec. (± 10 sec.) |
165 to 200 PSI | 40 sec. (± 05 sec.) |
37″ x 12.5″ | Fill Rate |
0 to 30 PSI | 5 min. 00 sec. (± 15 sec.) |
15 to 30 PSI | 2 min. 30 sec. (± 10 sec.) |
40″ x 15.5″ | Fill Rate |
0 to 30 PSI | 5 min. 25 sec. (± 15 sec.) |
15 to 30 PSI | 2 min. 40 sec. (± 10 sec.) |
* Supply Voltage: 13.8 Volts
* Due to redundant restrictions added to apparatus, for flow rate testing, actual flow rate at 0 psi may vary.
*Jeep is a registered trademark of FCA US LLC and is used for identification purposes only. FCA US LLC. does not sponsor or approve this product and is not affiliated or connected in any manner with VIAIR Corporation.