495C
Tank
Fill Rates |
| |
2.5
Gallon Tank |
Fill
Rate |
| |
0
To 145 PSI |
2 min. 02 sec. |
| |
0
To 175 PSI |
2 Min. 46 Sec. |
| |
110
To 145 PSI |
45 Seconds |
| |
140
To 175 PSI |
43 Seconds |
| |
|
|
| |
5
Gallon Tank |
Fill
Rate |
| |
0
To 145 PSI |
4 Min. 12 Sec. |
| |
0
To 175 PSI |
5 Min. 39 Sec. |
| |
110
To 145 PSI |
1 min. 15 Sec. |
| |
140
To 175 PSI |
1 min. 28 sec. |
 |
|
|
The
495C features include horizontal cooling fins and a trapezoidal
head design, a standard 3/8” stainless steel braided
leader hose with inline check valve and insulated wiring
for simple installation. * Must be used with a 175 PSI or
lower pressure, non-adjustable pressure switch when used
with an air tank.
|
495C
Performance Data |
| |
PSI |
CFM |
A |
bar |
LPM |
A |
| |
0
|
2.37 |
21 |
0 |
67.0 |
21 |
| |
10 |
2.29 |
23 |
1.0 |
64.0 |
24 |
| |
20 |
2.19 |
25 |
2.0 |
60.0 |
28 |
| |
30 |
2.08 |
29 |
3.0 |
55.0 |
32 |
| |
40 |
1.97 |
31 |
4.0 |
51.0 |
33 |
| |
50 |
1.87 |
33 |
5.0 |
47.0 |
35 |
| |
60 |
1.76 |
33 |
6.0 |
44.0 |
35 |
| |
70 |
1.69 |
35 |
7.0 |
41.0 |
35 |
| |
80 |
1.62 |
35 |
8.0 |
38.0 |
34 |
| |
90 |
1.55 |
35 |
9.0 |
34.0 |
34 |
| |
100 |
1.48 |
35 |
10.0 |
31.0 |
33 |
| |
110 |
1.41 |
34 |
11.0 |
28.0 |
32 |
| |
120 |
1.30 |
34 |
12.0 |
25.0 |
31 |
| |
130 |
1.20 |
34 |
13.0 |
23.0 |
30 |
| |
140 |
1.13 |
33 |
14.0 |
20.0 |
29 |
| |
150 |
1.06 |
33 |
|
|
|
| |
160 |
1.00 |
32 |
|
|
|
| |
170 |
0.92 |
32 |
|
|
|
| |
175 |
0.88 |
31 |
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
*Supply
Voltage: 13.8 Volts |
 |
|