FEATURES |
---|
– Thermal Overload Protector |
– Check Valve |
– Vibration Isolators |
– Mounting Hardware |
– Stainless Steel Braided Leader Hose |
– Air Line for Remote Mount Air Filter |
– Remote Mount Air Filter Assembly |
– (2) Replacement Air Filter Elements |
– Installation Instructions |
– |
– |
– |
– |
– |
– |
– |
– |
– |
SPECIFICATIONS |
---|
– 12-Volt |
– Permanent Magnetic Motor |
– Duty Cycle: 33% @ 100 PSI |
– Max. Working Pressure: 150 PSI |
– Max. Air Tank Size: 5.0 Gallon |
– Max. 12V Amp Draw: 30-Amps |
– Ingress Protection Rating: IP67 |
– Max Ambient Temp: +158°F |
– Min Ambient Temp: -40°F |
– Dimensions: 10″L x 4.3″W x 6.5″H |
– Net Weight: 9.00 lbs. |
– |
– |
– |
– |
– |
– |
– |
RECOMMENDED COMPONENTS | |||||
---|---|---|---|---|---|
– 0.5 Gallon Tank (P/N 91005) | |||||
– 1.0 Gallon Tank (P/N 91010) | |||||
– 1.5 Gallon Tank (P/N 91015) | |||||
– 2.0 Gallon Tank (P/N 91022) | |||||
– 2.5 Gallon Tank (P/N 91025) | |||||
– 5.0 Gallon Tank (P/N 91050) | |||||
– 12V Relay (P/N 93940) | |||||
– 12V Sealed Relays (P/N 93944, 93950) | – Pressure Switches (P/N 90100, 90101, 90102) |
||||
– Pressure Switches w/ Relay (P/N 90110, 90111, 90113) |
|||||
– Sealed Pressure Switches (P/N 90217, 90223, 90227) |
|||||
– Leader Hose w/out Check Valve (P/N 92802, 92804, 92809) |
|||||
– Leader Hose w/ Check Valve (P/N 92793, 92805) |
* For 12V Only.
Please Note: Use thread sealant for proper installation. Thread tape is not recommended.
Properly sealed, recommended torque for 1/8” is 10 ~ 11 ft. lbs. Recommended torque for 1/4” and 3/8” is 16 ~ 18 ft. lbs.
PERFORMANCE DATA
PSI | CFM | A | BAR | LPM | A |
---|---|---|---|---|---|
0 | 2.95 | 16 | 0 | 85.0 | 16 |
10 | 2.38 | 18 | 1.0 | 66.0 | 19 |
20 | 2.21 | 21 | 2.0 | 62.0 | 23 |
30 | 2.12 | 23 | 3.0 | 58.0 | 25 |
40 | 2.03 | 25 | 4.0 | 53.0 | 27 |
50 | 1.92 | 26 | 5.0 | 49.0 | 27 |
60 | 1.80 | 27 | 6.0 | 44.0 | 28 |
70 | 1.69 | 28 | 7.0 | 40.0 | 28 |
80 | 1.58 | 28 | 8.0 | 37.0 | 28 |
90 | 1.47 | 28 | 9.0 | 34.0 | 28 |
100 | 1.34 | 28 | 10.0 | 31.0 | 27 |
110 | 1.28 | 28 | |||
120 | 1.17 | 27 | |||
130 | 1.12 | 27 | |||
140 | 1.02 | 27 | |||
150 | 0.95 | 27 |
* Supply Voltage: 13.8 Volts
FILL RATES
2.5 Gallon Tank | Fill Rate |
---|---|
0 to 105 PSI | 1 min. 27 sec. (± 05 sec.) |
85 to 105 PSI | 21 sec. (± 03 sec.) |
0 to 145 PSI | 2 min. 20 sec. (± 05 sec.) |
110 to 145 PSI | 48 sec. (± 03 sec.) |
5.0 Gallon Tank | Fill Rate |
0 to 105 PSI | 2 min. 55 sec. (± 10 sec.) |
85 to 105 PSI | 45 sec. (± 05 sec.) |
0 to 145 PSI | 4 min. 50 sec. (± 10 sec.) |
110 to 145 PSI | 1 min. 40 sec. (± 05 sec.) |
* Due to redundant restrictions added to apparatus, for flow rate testing, actual flow rate at 0 psi may vary.