280C
Tank
Fill Rates
|
| |
2.5
Gallon Tank |
Fill
Rate |
| |
0
To 105 PSI |
2
Min. 55 Sec. |
| |
0
To 145 PSI |
4
Min. 41 Sec. |
| |
85
To 105 PSI |
44
Seconds |
| |
110
To 145 PSI |
1
Min. 36 Sec. |
| |
|
|
| |
5
Gallon Tank |
Fill
Rate |
| |
0
To 105 PSI |
5
Min. 26 Sec. |
| |
0
To 145 PSI |
8
Min. 52 Sec. |
| |
85
To 105 PSI |
1
Min. 17 Sec. |
| |
110
To 145 PSI |
2
Min. 52 Sec. |
 |
|
|
The
280C is rated to 150 PSI maximum working pressure. Features
include a standard ¼” stainless steel braided
leader hose with inline check valve and insulated wiring
for simple installation. *Must be used with a 150 PSI or
lower pressure, non-adjustable pressure switch when used
with an air tank
|
280C
Performance
Data
|
| |
PSI
|
CFM
|
A
|
bar
|
LPM
|
A
|
| |
0
|
1.31 |
8 |
0 |
37.0 |
8 |
| |
10 |
1.29 |
9 |
1.0 |
33.0 |
10 |
| |
20 |
1.15 |
10 |
2.0 |
31.5 |
11 |
| |
30 |
1.11 |
12 |
3.0 |
29.0 |
13 |
| |
40 |
1.04 |
13 |
4.0 |
26.5 |
14 |
| |
50 |
0.99 |
13 |
5.0 |
24.0 |
14 |
| |
60 |
0.92 |
14 |
6.0 |
22.0 |
15 |
| |
70 |
0.87 |
14 |
7.0 |
21.0 |
15 |
| |
80 |
0.81 |
15 |
8.0 |
19.5 |
16 |
| |
90 |
0.76 |
15 |
9.0 |
17.5 |
15 |
| |
100 |
0.74 |
15 |
10.0 |
15.5 |
15 |
| |
110 |
0.71 |
15 |
|
|
|
| |
120 |
0.67 |
16 |
|
|
|
| |
130 |
0.62 |
15 |
|
|
|
| |
140 |
0.57 |
15 |
|
|
|
| |
150 |
0.51 |
15 |
*Supply
Voltage: 13.8 Volts
|
 |
|